Introduuction
There are numerous industrial equipment on the market from different manufacturers and with different characteristics for industrial automation applications. However, as companies develop, it is often necessary to migrate to newer equipment without losing sight of the necessary compatibility with other equipment. Sometimes the old equipment cannot be replaced and, to solve this problem, it is necessary to integrate different technologies from different manufacturers, protocols and generations. The integration of technologies with different protocols present difficulties when they aren’t compatible since each protocol has its own characteristics, being necessary to make them compatible so that they can communicate directly or indirectly. Usually, this compatibility attempt is not perfect, it can present delays in communication and in some cases it is necessary to use special equipment such as bridges, routers and gateways in order to convert and satisfy all layers of the OSI model necessary for the integration to succeed. This article provides the development of a remote interface solution from its early design to HMI interface.
Keywords
Industrial Automation fieldbus; Remote interface; PROFINET; Modbus TCP/IP; Modbus RTU.
Integrated networks
Development of the integrated solution
The equipment used in this work is shown in Table I. The main goal of this work is to demonstrate the integration/connection of individual workstations, each one with a ILC131ETH PLC, operating as PROFINET fieldbus devices with a test workbench that has available an old generation S7-216 PLC from Siemens. The test workbench is used for operators to test the software developed in each individual workstations. Since there is only a single test workbench it is necessary to create conditions to redirect the communication of each individual workstations to the test workbench whenever necessary. Figure 1 illustrates the proposed solution developed in this work.
Equipment | Manufacture | Communication Protocol |
ILC 131 ETH PLC | Phoenix Contact | PROFINET |
FL SWITCH SMCS 8TX-PN | Phoenix Contact | PROFINET |
AXC1050PN PLC | Phoenix Contact | PROFINET |
MODBUS TCP | ||
USR-N510 Converter, Serial Port: RS232/RS485/RS422,3-in-1 Serial ports | Jinan USR IOT Technology Limited | MODBUS TCP |
MODBUS RTU | ||
S7-216 PLC | Siemens | MODBUS RTU |

Since the communication protocol of the workstations devices is not compatible with the protocol of the PLC available at the test workbench, it was necessary to use additional equipment and develop software to allow this connection. The AXC1050PN PLC was the solution adopted, since it operates as PROFINET fieldbus controller and can communicate with up to sixteen PROFINET devices, such as the ILC131ETH PLC available in each workstations. This PLC also supports the Modbus TCP/IP protocol and incorporates a dedicated Webserver.
Armando Cordeiro* and Daniel Santiago
DEEEA, LCEC, Instituto Superior de Engenharia de Lisboa,
Instituto Politécnico de Lisboa Lisbon, Portugal
*armando.cordeiro@isel.pt; Tel: (+351) 218 317 000
Para ler o artigo ou dossier completo faça a subscrição da revista e obtenha gratuitamente o link de download da revista “robótica” nº133. Pode também solicitar apenas este artigo através do email: a.pereira@cie-comunicacao.pt
Outros artigos relacionados
- Artigo “Extending I/O Interfaces for Phoenix Contact PLC using ESP-NOW wireless microcontrollers” da edição 132 da revista robótica;
- Artigo “Kyland” da edição 115 da revista robótica;
VOCÊ PODE GOSTAR
-
Strategies to Reduce Power Consumption in pico-Satellites
-
Unusual Robotic Arm [Braço robótico incomum]
-
Extending I/O Interfaces for Phoenix Contact PLC using ESP-NOW wireless microcontrollers
-
Neptune.Controller: smart system for water assisted injection moulding based on fluid flow and heat transfer
-
Robot colaborativo em tarefas de polimento